Specification: Part Number 1034981 EMC: According to EN 61000-6-2 and EN 61000-6-3 Repeat accuracy: 0.005 ° Electrical interface: Cable, 22-pin, axial, 5 m Max. number of revolutions: 1 Operating voltage range: 10 V DC ... 32 V DC Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Measuring step: 360 ° /number of lines Working temperature range: -20 °C ... 85 °C Initialization time: 80 ms Storage temperature range: -40 °C ... 100 °C Enclosure rating: IP 66, according to IEC 60529 Resistance to shocks: 50 g (according to EN 60068-2-27) Resolution power: 360 x 1 Max. number of steps per revolution: 360 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Measuring step deviation: 0.005 °, 0.016 ° Operating power consumption (no load): 90 mA Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps)