ARS60-FDK02000

Specification: Part Number 1035861 Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Measuring step deviation: 0.005 °, 0.016 ° EMC: (according to EN 61000-6-2 and EN 61000-6-3) Resolution power: 2,000 x 1 MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Working temperature range: -20 °C ... 85 °C Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Operation of zero-set: ≥ 100 ms Operating voltage range: 10 V DC ... 32 V DC Bearing lifetime: 3.6 x 10^9 revolutions Operating power consumption (no load): 90 mA Max. number of steps per revolution: 2,000 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Resistance to shocks: 50 g (according to EN 60068-2-27) Enclosure rating: IP 64 (according to IEC 60529) Maximum operating speed: 3,000 /min Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Electrical interface: Cable, 22-pin, radial, 1.5 m Initialization time: 80 ms Max. number of revolutions: 1 Start up torque: 2.2 Ncm Max. angular acceleration: 500,000 rad/s² Shaft diameter: 6 mm 8 mm 10 mm 12 mm 14 mm 15 mm 1/4 " 3/8 " 1/2 " Measuring step: 360 ° /number of lines Repeat accuracy: 0.005 ° Storage temperature range: -40 °C ... 100 °C Mechanical interface: Through hollow shaft Operating torque: 1.6 Ncm
Part Number ARS60-FDK02000
Manufacture SICK
  • 1+ million product
    50+ Manufacturers
  • Free Shipping
    For orders from $50
  • Support 24/7
    Call us anytime
  • 100% Safety
    Only secure payments
Menu
Mail Us
enquiry@onstocktrading.com