Specification: Part Number 1031835 Enclosure rating: IP 64 (according to IEC 60529) Storage temperature range: -40 °C ... 100 °C Start up torque: 2.2 Ncm Mechanical interface: Through hollow shaft Measuring step deviation: 0.005 °, 0.016 ° EMC: (according to EN 61000-6-2 and EN 61000-6-3) Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Working temperature range: -20 °C ... 85 °C Bearing lifetime: 3.6 x 10^9 revolutions Operating torque: 1.6 Ncm Electrical interface: Cable, 11-pin, radial, 5 m Operating voltage range: 10 V DC ... 32 V DC Max. angular acceleration: 500,000 rad/s² Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Operating power consumption (no load): 60 mA Max. number of steps per revolution: 32,767 Operation of zero-set: ≥ 100 ms Repeat accuracy: 0.005 ° MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Measuring step: 360 ° /number of lines Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Initialization time: 80 ms Maximum operating speed: 3,000 /min Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Resolution power: 32,767 x 1 Resistance to shocks: 50 g (according to EN 60068-2-27) Max. number of revolutions: 1 Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Shaft diameter: 6 mm 8 mm 10 mm 12 mm 14 mm 15 mm 1/4 " 3/8 " 1/2 "