Specification: Part Number 1038059 CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Max. number of revolutions: 1 EMC: (according to EN 61000-6-2 and EN 61000-6-3) Storage temperature range: -40 °C ... 100 °C, without package SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Operating torque: 0.6 Ncm (20 °C) MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Max. angular acceleration: 500,000 rad/s² Code sequence: CW/CCW, parameter adjustable Initialization time: 50 ms Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Resolution power: 1,024 x 1 Code type: Gray Type of mounting shaft: Through hollow shaft Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Moment of inertia of the rotor: 40 gcm² Connection type: Cable, 8-wire, universal, 1.5 m Clock frequency: 1 MHz Maximum operating speed: 9,000 /min Working temperature range: 0 °C ... 85 °C Measuring step deviation: ± 0.2 ° Reverse polarity protection: 1 Mechanical interface: Through hollow shaft Enclosure rating: IP 65 (according to IEC 60529), housing side, IP 65 (according to IEC 60529), shaft side Start up torque: 0.8 Ncm (20 °C) Shaft diameter: 10 mm Operating voltage range: 4.5 V DC ... 32 V DC Interface signals: Clock +, Clock -, Data +, Data- Electrical interface: SSI/Gray Max. number of steps per revolution: 1,024 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Measuring step: 0.09 ° 360 ° / number of steps Repeat accuracy: 0.002 ° Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Error limits: ± 0.3 ° Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Power consumption: 0.5 W (without load) Bearing lifetime: 3.0 x 10^9 revolutions