Specification: Part Number 1053363 Initialization time: 50 ms Measuring step: 0.01 ° Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Electrical interface: SSI/Gray, programmable Working temperature range: -30 °C ... 100 °C Operating voltage range: 4.5 V DC ... 32 V DC Start up torque: 0.8 Ncm (20 °C) Mechanical interface: Through hollow shaft Clock frequency: 2 MHz MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Measuring step deviation: ± 0.01 ° Connection type: Cable, 8-wire, universal, 1.5 m Reverse polarity protection: 1 Maximum operating speed: 9,000 /min Max. number of revolutions: 1 Code sequence: CW/CCW, parameter adjustable Shaft diameter: 8 mm Repeat accuracy: 0.002 ° Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Max. number of steps per revolution: 32,768 Enclosure rating: IP 65 (according to IEC 60529), housing side, IP 65 (according to IEC 60529), shaft side Error limits: ± 0.05 ° Resistance to shocks: 70 g, 6 ms (according to EN 60068-2-27) Operating torque: 0.6 Ncm (20 °C) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Max. angular acceleration: 500,000 rad/s² Interface signals: Clock +, Clock -, Data +, Data- Power consumption: 0.5 W (without load) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Code type: Gray Bearing lifetime: 3.0 x 10^9 revolutions Resolution power: 32,768 x 1 Type of mounting shaft: Through hollow shaft Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Storage temperature range: -40 °C ... 100 °C, without package Moment of inertia of the rotor: 40 gcm² CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)