MAIN CHARACTERISTICS range of product PREVENTA SAFETY DETECTION product or component type SAFETY MODULE safety module name XPSCM safety module application F MNTRG OF 1 BEAM PH-ELEC SSR function of module BUILT-IN MUTING safety level CAN REACH CATEGORY 2 CONFORMING TO ENISO 13849-1 WITH THE APPROPRIATE CONTROL SYSTEM AND CORRECTLY WIRED safety reliability data MTTFD = 16.6 YEARS CONFORMING TO ENISO 13849-1 number of inputs 2 TERMINALS MA MB FOR MUTING FUNCTION input voltage 24 V DC FOR SENSOR input compatibility XC LIMIT SWITCH FOR MUTING FUNCTION connections - terminals CAPTIVE SCREW CLAMP TERMINALS CLAMPING CAPACITY 1 X 0.14...1 X 2.5 MM SOLID OR FLEXIBLE CABLE WITHOUT CABLE END output type RELAY 2 NO 13-14 23-24 VOLT-FREE number of additional circuits 0 [Us] rated supply voltage 24 V DC - 20..20 COMPLEMETARY CHARACTERISTICS sensor power supply 24 V DC TERMINALS U+ U- supply current for sensors < 200 MA input current < 200 MA FOR MUTING FUNCTION synchronisation time between inputs 3 S +- 20 FOR THE ACTIVATION OF THE MAMB MUTING SIGNAL muting maximum duration 60 S - 10..30 line resistance