MAIN CHARACTERISTICS range of product PREVENTA SAFETY AUTOMATION product or component type PREVENTA SAFETY MODULE safety module name XPSBA safety module application ELC MNTRG OF 2-HAND CTRL STTS function of module MNTRG TWO-HAND CONTROL STATION safety level CAN REACH PL CCATEGORY 1 CONFORMING TO ENISO 13849-1 safety reliability data MTTFD = 160.8 YEARS CONFORMING TO ENISO 13849-1 connections - terminals CAPTIVE SCREW CLAMP TERMINALS CLAMPING CAPACITY 1 X 0.14...1 X 2.5 MM FLEXIBLE CABLE WITHOUT CABLE END output type RELAY 1 NO VOLT-FREE number of additional circuits 1 NC [Us] rated supply voltage 115 V AC - 15..15 COMPLEMETARY CHARACTERISTICS synchronisation time between inputs 0.5 S supply frequency 50 60 HZ power consumption in VA